  Minimum Average Values
Property Test Method 0.75 mm 1.00 mm 1.50 mm 2.00 mm 2.50 mm

Thickness, microns ASTM D 5199          
   minimum average   750 1,000 1,500 2,000 2,500
   lowest individual reading   675 900 1,350 1,800 2,250

Sheet Density, g/cc ASTM D 1505/D 792 0.940 0.940 0.940 0.940 0.940

Tensile Properties 1 ASTM D 6693
         
1. Yield Strength, kN/m   11 15 22 29 37
2. Break Strength, kN/m   20 27 40 53 67
3. Yield Elongation, %   12 12 12 12 12
4. Break Elongation, %   700 700 700 700 700

Tear Resistance, N ASTM D 1004 93 125 187 249 311

Puncture Resistance, N ASTM D 4833 240 320 480 640 800

Stress Crack Resistance 2, hrs ASTM D 5397 (App.) 300 300 300 300 300

Carbon Black Content 3, % ASTM D 1603 2.0 - 3.0 2.0 - 3.0 2.0 - 3.0 2.0 - 3.0 2.0 - 3.0

Carbon Black Dispersion 4 ASTM D 5596     -Note 4-    

Oxidative Induction Time (OIT)            
Standard OIT, minutes ASTM D 3895 100 100 100 100 100

Oven Aging at 85°C ASTM D 5721          
High Pressure OIT
(% retained after 90 days)
ASTM D 5885 80 80 80 80 80

UV Resistance 5 ASTM D 7238          
High Pressure OIT 6
(% retained after 1600 hrs)
ASTM D 5885 50 50 50 50 50

Roll Dimensions ASTM D 6392           
1. Width (meters):   7 7 7 7 7
2. Length (meters)   304.9 228.7 152.4 114.3 91.5
3. Area (square meters):   2,137 1,603 1,068 801 641
4. Gross Weight (kilograms, approx.) 1,574 1,574 1,574 1,574 1,574

1. Machine direction (MD) and cross machine direction (XMD) average values should be on the basis of 5 test specimens
    each direction. Yield elongation is calculated using a gauge length of 33 mm; Break elongation is calculated using a
    gauge length of 50 mm.
2.
The yield stress used to calculate the applied load for the SP-NCTL test should be the mean value via MQC testing.
3. Other methods such as ASTM D 4218 or microwave methods are acceptable if an appropriate correlation can be
    established.
4. Carbon black dispersion for 10 different views: 9 in Categories 1 and 2 with one allowed in category 3.
5.
The condition of the test should be 20 hr. UV cycle at 75°C followed by 4 hr. condensation 60°C.
6.
UV resistance is based on percent retained value regardless of the original HP-OIT value.

This data is provided for informational purposes only and is not intended as a warranty or guarantee. Poly-America assumes no responsibility in connection with the use of this data. These values are subject to change without notice. REV. 08/11

 