SMOOTH HDPE GEOMEMBRANE ENGLISH UNITS |
|
Minimum Average Values |
Property |
Test Method |
30 Mil |
40 Mil |
60 Mil |
80 Mil |
100 Mil |
|
Thickness, mils |
ASTM D 5199 |
|
|
|
|
|
minimum average |
|
30 |
40 |
60 |
80 |
100 |
lowest individual reading |
|
27 |
36 |
54 |
72 |
90 |
|
Sheet Density, g/cc |
ASTM D 1505/D 792 |
0.940 |
0.940 |
0.940 |
0.940 |
0.940 |
|
Tensile Properties
1 |
ASTM D 6693
|
|
|
|
|
|
1. Yield Strength, lb/ in |
|
63 |
84 |
126 |
168 |
210 |
2. Break Strength, lb/ in |
|
114 |
152 |
228 |
304 |
380 |
3. Yield Elongation, % |
|
12 |
12 |
12 |
12 |
12 |
4. Break Elongation, % |
|
700 |
700 |
700 |
700 |
700 |
|
Tear Resistance, lb |
ASTM D 1004 |
21 |
28 |
42 |
56 |
70 |
|
Puncture Resistance, lb |
ASTM D 4833 |
54 |
72 |
108 |
144 |
180 |
|
Stress Crack Resistance
2, hrs |
ASTM D 5397 (App.) |
300 |
300 |
300 |
300 |
300 |
|
Carbon Black Content
3, % |
ASTM D 1603 |
2.0 - 3.0 |
2.0 - 3.0 |
2.0 - 3.0 |
2.0 - 3.0 |
2.0 - 3.0 |
|
Carbon Black Dispersion
4 |
ASTM D 5596 |
--Note 4-- |
|
Oxidate Induction Time (OIT) |
|
|
|
|
|
|
Standard OIT, minutes |
ASTM D 3895 |
100 |
100 |
100 |
100 |
100 |
|
Oven Aging at 85°C |
ASTM D 5721 |
|
|
|
|
|
High Pressure OIT
(% retained after 90 days) |
ASTM D 5885 |
80 |
80 |
80 |
80 |
80 |
|
UV Resistance
5 |
ASTM D 7238 |
|
|
|
|
|
High Pressure OIT
6
(% retained after 1600 hrs) |
ASTM D 5885 |
50 |
50 |
50 |
50 |
50 |
|
Roll Dimensions |
|
|
|
|
|
|
1. Width (feet): |
|
23 |
23 |
23 |
23 |
23 |
2. Length (feet) |
|
1000 |
750 |
500 |
375 |
300 |
3. Area (square feet): |
|
23,000 |
17,250 |
11,500 |
8,625 |
6,900 |
4. Gross Weight (pounds, approx.) |
3,470 |
3,470 |
3,470 |
3,470 |
3,470 |
|
1. Machine direction (MD) and cross machine direction (XMD) average values should be on the basis of 5 test specimens each direction. Yield elongation is calculated using a gauge length of 1.3 inches; Break elongation is calculated using a gauge length of 2.0 inches.
2. The yield stress used to calculate the applied load for the SP-NCTL test should be the mean value via MQC testing.
3. Other methods such as ASTM D 4218 or microwave methods are acceptable if an appropriate correlation can be established.
4. Carbon black dispersion for 10 different views: 9 in Categories 1 and 2 with one allowed in category 3.
5. The condition of the test should be 20 hr. UV cycle at 75°C followed by 4 hr. condensation 60°C.
6. UV resistance is based on percent retained value regardless of the original HP-OIT value.
This data is provided for informational purposes only and is not intended as a warranty or guarantee. Poly-America. assumes no responsibility in connection with the use of this data. These values are subject to change without notice. REV. 08/11
|
|
|
|
|